Ademco vista 32fb manual




















Get Started. Works With. Replacement Parts. Related Products. Sell Train Install Promote. View All View Less. Failure to have the installation performed by a qualified professional could result in substantial property damage, and even severe personal injury or death, and Resideo will not be responsible for any damages or injuries resulting from not observing this warning. Commercial fire and burglary partitioned security systems with scheduling 81 pages.

Commercial burglary partitioned security systems pages. Commercial burglary partitioned security system with scheduling 80 pages. Page 5: System Overview System Overview General Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategically positioned throughout the premises. The system offers you three forms of protection: burglary, fire and emergency. The keypad provides full control of system operation. For the most part, you as a user need not know about other users and their structure in the system, but from time to time, you may see display messages which indicate the system is in use by another user.

This feature can be used to make it easy to perform multiple functions at once such as going to another partition to bypass a zone , or it can be used to simplify an everyday, repeated procedure.

Your keypads allow you to control all system functions. The keypads feature a telephone style digital keypad and a Liquid Crystal Display LCD that shows the nature and location of all occurrences. When using the keypad to enter codes and commands, sequential key depressions must be made within 3 seconds of one another.

Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing.

In summary, there are six authority levels, each having certain system restrictions as shown below. CODE 1. Enter Master or Manager code and press the key. Enter the new code for that user. But, if the user is authorized, a keypad in one partition can be used to perform system functions in other partitions by using the GOTO command. Faulted zones in all the selected partitions will be displayed.

These faults must be corrected or bypassed. In addition, receivers should be programmed via Device programming.

After programming all system related programming fields in the usual way, press 93 while still in programming mode to display the first choice of the menu driven programming functions.

Enter the zone type desired or change it, if necessary. Page 15 If response type 27 selected, this prompt will be displayed. Page Menu Mode If the serial number transmitted does not match the serial number entered, a display Entd A similar to the one at the left will appear. If the loop number does not match, it will also be Rcvd A displayed.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained i. These categories represent the main menu options found in Report Code Programming. Reports and the categories in which they Press [ ].

Enter the second digit of the report. Page 25 To add an s or 's , if needed, press 2. The first depression adds an s , the second depression adds an ' s , the third depression displays no character to erase the character , the fourth depression adds an s , etc.

Accept the word. Page 26 Custom Words Up to 60 installer-defined words can be added to the built-in vocabulary. Each of the 60 words can actually consist of several words, but bear in mind that a maximum of 10 characters can be used for each word string.

To select a word, press [ ] followed by the word's 3-digit number. NOTE: This vocabulary is not to be used for relay voice descriptors. Enter the first digit of the System Low Battery Restore report. Enter the first digit of the System AC Loss report. Enter the first digit of the System AC Restore report. Enter the first digit of the System Test report. Enter the first digit of the System Power-Up report.

Enter the first digit of the Cancel report. Enter the first digit of the Program Tamper report. To enter System Group 2 codes, press 1. Enter the first digit of the Event Log Overflow report. Enter the first digit of the Exit Error by Zone report. Enter the first digit of the Exit Error by User report. Enter the first digit of the Recent Close report.